- Rapport
- Kärnkraft
Methods for Locating Pool Liner Leakage at Nuclear Power Plants

A state-of-the-art review is complemented by targeted EMAT shear-horizontal guided-wave experiments, which clarify detection mechanisms and practical limitations. Based on the combined findings, Alternating Current Field Measurement (ACFM) is identified as the most promising near-term technique for locating surface-breaking cracks, with Phased Array Ultrasonic Testing (PAUT) as a complementary method for detailed characterization. The results provide an application-oriented basis for prioritizing inspection techniques and guiding future development toward more reliable leakage localization with reduced downtime.
Rapporter och publikationer
Här listas rapporter och resultatblad från programmet.
- Rapport
Bestämning av korrosionsskyddsförmågan för olika reparationsbruk vid partiella reparationer
Denna rapport sammanfattar resultaten från ett omfattande forsknings och utvecklingsprojekt genomfört bland annat inom Trafikverkets BBT program och Betongtekniskt program kärnkraft.
|2026:1186Bror Sederholm, Johan Ahlström, Jan Trägårdh
- Rapport
Gap formation between steel liner and cylinder wall in reactor containment buildings
The reactor containment building is the most important safety barrier in a nuclear power plant. It is a cylindrical, prestressed concrete structure with an embedded steel liner on the inner face of the containment wall, designed to maintain integrity in the event of an internal accident.
|2026:1181Nils Janestad, Manouchehr Hassanzadeh, Camilo Rito Pi och Elin Torén Johansson
- Rapport
Methods for detection of rebar in nuclear concrete structures
This project has reviewed non-destructive methods for detecting reinforcement in concrete structures and clarified which tasks can be performed by technically skilled in- house personnel and when specialist support is required.
|2026:1182Magnus Nilson
- Rapport
Deformationer och töjningar resulterande av håltagning i reaktorinneslutning på Ringhals 2
Två öppningar skapades i Ringhals 2:s reaktorinneslutning för att ta ut utrustning.
|2026:1179Manouchehr Hassanzadeh, Sweco